background
background

Endostar RE Re Endo Rotary System

Rotary system used to efficiently remove old fillings from the canal during root canal retreatment.

Endostar RE Re Endo Rotary System is a rotary system used to efficiently remove old fillings from the canal during root canal retreatment. The kit contains 4 instruments, with tapers from 04 to 12 and size 30. It was designed to work with the crown-down technique. The kit includes:

  • Two K-type files with a square cross-section, with 4 cutting edges and good elasticity.
  • Two files with a S-type blade with two edges distributed symmetrically 180 degrees to the axis of symmetry and a cutting channel at an angle of 90 degrees. They present with great cutting ability, a non-cutting apex and very good elasticity.

Recommended number of use:

Maximum of 5-10 times, depending on the size (see Table), provided that visual inspection performed by the practitioner prior to use shows that the instrument remains undamaged, is not bent, deformed, does not show signs of blade wear and can be securely attached to the handpiece. If the file has been subjected to high torsion force, especially in highly curved canals the instrument should be used only once.

Files should be used with motor speed between 150 and 300 rpm.

The torque settings indicated in the table above table are for example only and may vary according to each user preferences and motor capabilities. Do not exceed the upper torque limit which is different for each instrument. If precise torque settings cannot be set, and only manufacturer-specific torque levels are available, be sure to select one that does not exceed the recommended limit.

 

 

Clinical instruction for use

Rinse the canal each time after the file is used. Clean the files of any debris repeatedly.

    1. Make sure you have proper access to the gutta-percha filled canal.
    2. Add a few drops of the gutta-percha dissolving agent.
    3. Use the Endostar RE Re Endo Rotary System – numbers 1-4 combined with the crown-down technique. Starting with file No. 1, then work your way down to file No. 4.
    4. Make sure the old filling is entirely removed from the canal. We recommend that an x-ray image is taken.
    5. Perform final cleaning of the canal. Rinse with solutions normally used for canal rinsing during endodontic treatment.

 

background

CE mark

background

Nickel-titanium alloy

background

Sterilization

Autoclave in 134 degrees. Recommended sterilization time: 3 minutes at 2.1 bar overpressure.

Instrument

Number of strips

Taper (%)

ISO

Lenght

Nr 1

1

12

30

17 mm

Nr 2

2

08

30

23 / 25 / 28 mm

Nr 3

3

06

30

23 / 25 / 28 mm

Nr 4

4

04

30

23 / 25 / 28 mm

Endostar RE Re Endo Rotary System

Intro set, 30/12 (17mm), 30/08, 30/06, 30/04, 4 pcs, 23 mm

RE23

Intro set, 30/12 (17mm), 30/08, 30/06, 30/04, 4 pcs, 25 mm

RE

Intro set, 30/12 (17mm), 30/08, 30/06, 30/04, 4 pcs. 28 mm

RE28

Endostar RE Re Endo Rotary System

Refill, 30/12, 6 pcs, 17 mm

RE301217

Refill, 30/08, 6 pcs. 23 mm

RE300823

Refill, 30/08, 6 szt,. 25 mm

RE300825

Refill, 30/08, 6 pcs,. 28 mm

RE300828

Refill, 30/06, 6 pcs., 23 mm

RE300623

Refill, 30/06, 6 pcs., 25 mm

RE300625

Refill, 30/06, 6 pcs., 28 mm

RE300628

Refill, 30/04, 6 pcs, 23 mm

RE300423

Refill, 30/04, 6 pcs., 25 mm

RE300425

Refill, 30/04, 6 pcs., 28 mm

RE300428

Copy link